• Title of article

    Energy consumption of atria; the case of a commercial‐office center in the semi‐arid climate of Tehran

  • Author/Authors

    Ghazanfari, Fatemeh Department of Architecture - West Tehran Branch - Islamic Azad University West Tehran Branch,Tehran , Kaboli, Mohammad Hadi Department of Architecture - Islamic Azad University - Damavand branch, Damavand

  • Pages
    24
  • From page
    211
  • To page
    234
  • Abstract
    According to the energy crisis in the world, optimization of energy consumption is indispensable. Technological advances in constructions and application of renewable energy resources demand saving energy. Atrium, as one of the construction elements, catches sufficient daylight and acts as a passive solar element and results in a decline of energy consumption. This research seeks to evaluate the impact of different positions of atrium on its energy performance; this embraces modelling three groups of spatial configuration of atriums in a given four‐story building. The total volume and area of atriums in all three groups are equal. DesignBuilder, the energy simulation software, is the platform for simulation and comparison. The results show that the number of atriums does not have a noticeable impact on energy consumption; however, the spatial configuration of atriums, specially the distance of atriums to external walls have a little impact on the annual energy consumption. Based on the purpose of a specific design, one can decide on whether to take into account the discrepancy.
  • Keywords
    Atrium , Daylight , Passive Solar Systems , Energy Simulation , Atrium Geometry
  • Journal title
    Astroparticle Physics
  • Serial Year
    2019
  • Record number