Title of article :
Spectrophotometric analysis of thrombolytic activity: SATA assay
Author/Authors :
Zamanlu, Masumeh Neurosciences Research Center (NSRC) - Tabriz University of Medical Sciences, Tabriz, Iran , Mohammadian, Reza Neurosciences Research Center (NSRC) - Tabriz University of Medical Sciences, Tabriz, Iran , Farhoudi, Mehdi Neurosciences Research Center (NSRC) - Tabriz University of Medical Sciences, Tabriz, Iran , Eskandani, Morteza Research Center for Pharmaceutical Nanotechnology - Biomedicine Institute - Tabriz University of Medical Sciences, Tabriz, Iran , Entekhabi, Nazila Faculty of Chemical and Petroleum Engineering - University of Tabriz, Tabriz, Iran , Rafi, Mohammad Department of Neurology - Jefferson Medical College, Philadelphia, Pennsylvanian, USA
Pages :
8
From page :
31
To page :
38
Abstract :
Introduction: Measurement of thrombolytic activity is crucial for research and development of novel thrombolytics. It is a key factor in the assessment of the effectiveness of conventionally used thrombolytic therapies in the clinic. Previous methods used for the assessment of thrombolytic activity are often associated with some drawbacks such as being costly, time-consuming, complex with low accuracy. Here, we introduce a simple, economic, relatively accurate and fast method of spectrophotometric analysis of thrombolytic activity (SATA) assay, standardized by tissue plasminogen activator (tPA), which can quantitatively measure in vitro thrombolytic activity. Methods: Blood clots were formed, uniformly, by mixing citrated whole blood with partial thromboplastin time (PTT) reagent, together with calcium chloride. Then, designated concentrations of tPA were added to the samples, and the released red blood cells from each clot were quantified using spectrophotometry (λmax=405nm) as an indicator of thrombolytic activity. The accuracy of the method was tested by assessment of dose-responsibility against R2 value obtained by linear equation and measurement of the limit of detection (LOD) and limit of quantification (LOQ). The SATA assay was validated in comparison with some currently used techniques. Results: A linear relationship was obtained between different concentrations of tPA versus the spectrophotometric absorbance of the related dilutions of lysed clots, at λmax=405nm. Calculated R2 values were greater than 0.9; with LOD of 0.90 µg/mL of tPA (436.50IU) and LOQ of 2.99 µg/mL of tPA (1450.15IU). Conclusions: Conclusively, the SATA assay is a very simple quantitative method with repeatable and reproducible results for estimating the potency of an unknown thrombolytic agent, and calculating the activity as delicate as 1 µg/mL of tPA (485 IU/mL of thrombolytic dose).
Keywords :
Clot lysis , Thrombolytic agent , In vitro thrombolysis , Thrombolytic therapy , Fibrinolysis
Journal title :
Astroparticle Physics
Serial Year :
2018
Record number :
2471593
Link To Document :
بازگشت