Title of article :
The Comparison between Spectral and Entropic Measures Following Fatigue in Erector Spinae Muscles
Author/Authors :
Talebian, Saeed Department of Physiotherapy - School of Rehabilitation - Tehran University of Medical Sciences , Saba, Maryam Department of Physiotherapy - School of Rehabilitation - Ahvaz Jundishapur University of Medical Sciences , Bagheri, Hossein Department of Physiotherapy - School of Rehabilitation - Tehran University of Medical Sciences , Olyaei, Gholamreza Department of Physiotherapy - School of Rehabilitation - Tehran University of Medical Sciences , Mousav, Shiva Department of Physiotherapy - School of Rehabilitation - Tehran University of Medical Sciences
Abstract :
Background: Surface electromyography (sEMG) of muscles is a non-invasive
tool that can be helpful in the assessment of muscle function and some motor
control evaluations. A loss of force, known as muscle fatigue is accompanied by
changes in muscle electrical activity. One of the most commonly used surface
EMG parameters which reflects paraspinal muscle fatigue during different
tasks and positions is median frequency. Although it is widely known that the
electromyography power spectrum shifts to lower frequencies during fatiguing
contraction, an opinion exists that the validity of spectral shifts in assessment
of fatigue is questionable. Some researchers have examined whether other
quantities derived from sEMG signals are better indicators for muscle fatigue.
Following cyclic flexion/extension and consequence fatigue, variation in sEMG
signals may be complex for study.
The aim of this study was to determine which of the median frequency (MF)
or entropic (ENTR) is more sensitive for measuring muscular fatigue in erector
spinae muscles during cyclic flexion/extension.
Methods: Surface electromyography of erector spine muscles was recorded
in 25 healthy subjects during cyclic dynamic contractions. The experimental
session consisted of two parts: measurement of Maximal Voluntary Contraction
(MVC), and performing the fatigue test. All subjects performed rhythmic
flexion/extension with 50% MVC loading against B-200 Isostation, about 4-6
minutes. The MF and ENTR of the muscle activities were computed to assess
muscular fatigue.
Results: Paired sample t-tests showed that MF and ENTR changes after fatigue
test were significant (P<0.001). Percentage changes of both MF and ENTR were
reduced, this reduction for ENTR was more than 40% (P<0.001).
Conclusion: It seems that the changes of ENTR in muscle activities have the
ability to measure muscular fatigue and is more sensitive in comparison to MF.
Keywords :
Surface EMG , Muscle fatigue , Entropy , Median frequency
Journal title :
Astroparticle Physics