Title of article
VISCOUS DAMPER PLACEMENT OPTIMIZATION IN CONCRETE STRUCTURES USING COLLIDING BODIES ALGORITHM and STORY DAMAGE INDEX
Author/Authors
Hashemi, M.R. Civil Engineering Departement - Semnan University, Semnan , Vahdani, R Civil Engineering Departement - Semnan University, Semnan , Gerami, M Civil Engineering Departement - Semnan University, Semnan , Kheyrodin, A Civil Engineering Departement - Semnan University, Semnan
Pages
18
From page
53
To page
70
Abstract
Dampers can reduce structural response under dynamic loads. Since dampers are costly, the
design of structures equipped with dampers should make their application economically
justifiable. Among the effective cost reduction factors is optimal damper placement. Hence,
this study intended to find the optimal viscous damper placement using efficient
optimization methods. Taking into account the nonlinear behavior of structure, this optimal
distribution can be determined through meeting story-wise damping requirements such that
the structure provides the minimum dynamic response and becomes economically justified.
To compare the effect of different damper placement layouts on structural response and
determine the objective function of optimization, the ratio of peak structural displacement to
yield displacement was used as the damage index and objective function of optimization.
Colliding Bodies' Optimization (CBO) algorithm was used for optimal damper placement. In
this study, the 3- and 4-story concrete frames with different damper placement conditions
were studied. Results confirmed the efficiency of the proposed method and algorithm in
optimal viscous damper placement in each story. It was also discovered that the application
of dampers on higher stories partially uniforms height-wise damage distribution and works
towards the design goals.
Keywords
viscous damper , damage index , optimization , optimal position , nonlinear analysis