Title of article :
Comparison of the EMG Frequency Spectrum of Lower Limb Muscles during Weight Training with Traditional and Novel Equipment
Author/Authors :
Jafarnezhadgero, AmirAli Department of Physical Education and Sport Sciences - Faculty of Educational Sciences and Psychology - University of Mohaghegh Ardabili, Ardabil, Iran , Sadri, Amirhosein Department of Physical Education and Sport Sciences - Faculty of Educational Sciences and Psychology - University of Mohaghegh Ardabili, Ardabil, Iran , Bahrami Sharif, Mohammad Mahdi Department of Physical Education and Sport Sciences - Faculty of Educational Sciences and Psychology - University of Mohaghegh Ardabili, Ardabil, Iran , AlipourSarinasirloo, Milad Department of Physical Education and Sport Sciences - Faculty of Educational Sciences and Psychology - University of Mohaghegh Ardabili, Ardabil, Iran
Pages :
13
From page :
19
To page :
31
Abstract :
Many practitioners and trainers advise designing and executing resistance training programs that include free weights and machines for strength training. The aim of the present study was to compare the frequencyspectrum of lower limb muscles during weight training with traditional and novel equipment.Fourteen healthy power lifters (age: 26±7 years) were participated in this study. A portable EMG system with six pairs of bipolar surface electrodes was used to record the electrical activity of the selected lower limb muscles at a sampling frequency of 1200 Hz. Participants had enough experience to perform Free Weights Squat, Smith Machine Squat, Smith Machine Squat with one leg and the Dead lift movements. Participants carried out each movement,5 times at an intensity equal to 50% of one-repetition-maximum level. The results showed higher median frequency of the vastus lateralis muscle during free weight single-leg squat than those that in the free weight squat(p=0.001) and dead lift (p=0.000) movements in lifting phase. Also, the median frequency of vastus lateralis muscle in single-limb squat withsmith machine was significantly higher than that in the dead lift movement (p=0.021). The median frequency spectrum of the gastrocnemius muscle in thefree weight squatmovementshowed a significant increase during the downward phase relative to the free weight single-leg squat movement (p=0.039). In order to strengthen vastus lateralis muscle in athletes or individuals with weak vastus lateralis muscle, free weight single-leg squat movement is more effective than those that in the other movements.
Farsi abstract :
هدف پژوهش حاضر مقايسه طيف فركانس عضلات اندام تحتاني طي طي تمرينات با وزنه با ابزار سنتي و جديد بود. چهارده پاورليفتر مرد سالم )سن: 7 ± 26 سال( در اين پژوهش شركت نمودند. از دستگاه الكترومايوگرافي با شش جفت الكترود سطحي جهت ثبت سيگنال هاي الكترومايوگرافي منتخبي از عضلات اندام تحتاني با فركانس نمونه برداري 1200 هرتز استفاده شد. شركت كننده ها تجربه كافي در اجراي حركت اسكات با و بدون دستگاه اسميت، اسكات تك پا با و بدون دستگاه اسميت، و حركت ليفت مرده را داشتند. شركت كننده ها هر حركت را 5 بار با شدتي برابر 50 درصد يك تكرار بيشينه اجرا نمودند. نتايج نشان مي دهد كه ميانه فركانس عضله پهن خارجي در حركت اسكوات آزاد تك پا طي فاز بالا آمدن نسبت به حركت اسكوات آزاد ( 001 / 0 = P ) و حركت ليفت ( 000 / 0 = P) به طور معناداري بالاتر بود. همچنين، ميانه فركانس پهن خارجي درحركت اسكوات تك پا با دستگاه اسميت به طور معناداري از حركت ليفت بالاتر بود (021 / 0 - P). ميانه طيف فركانس عضله دوقلو در حركت اسكوات آزاد طي فاز پايين آمدن نسبت به حركت اسكوات آزاد تك پا افزايش معناداري را نشان داد ( 039 / 0 - P ). جهت تقويت بهتر عضله پهن خارجي در ورزشكاران و يا افراد داراي ضعف عضله ي پهن خارجي، حركت اسكات آزاد تك پا نسبت به ساير حركت بهتر مي باشد.
Keywords :
Dead lift , Smith machine , Squat , Lower limb , Frequency spectrum