Title of article :
Dosimetry and Radioenhancement Comparison of Gold Nanoparticles in Kilovoltage and Megavoltage Radiotherapy using MAGAT Polymer Gel Dosimeter
Author/Authors :
Farahani, S Department of Medical Physics and Biomedical Engineering - Tehran University of Medical Sciences, Tehran, Iran , Riyahi Alam, N Department of Medical Physics and Biomedical Engineering - Tehran University of Medical Sciences, Tehran, Iran , Haghgoo, S Pharmaceutical Department - Food & Drug Laboratory Research Center - Food & Drug Organization (FDO), Tehran, Iran , Khoobi, M Nanobiomaterials Group - Pharmaceutical Sciences Research Center - Tehran University of Medical Sciences, Tehran, Iran , Geraily, Gh Department of Medical Physics and Biomedical Engineering - Tehran University of Medical Sciences, Tehran, Iran , Gorji, E Pharmaceutical Department - Food & Drug Laboratory Research Center - Food & Drug Organization (FDO), Tehran, Iran
Abstract :
Background: Numerous unique characteristics of the nanosized gold, including
high atomic number, low toxicity, and high biocompatibility make it one of the most
appropriate nanostructures to boost radiotherapy efficacy. Many in-vivo and in-vitro
investigations have indicated that gold nanoparticles (AuNPs) can significantly
increase tumor injuries in low kilovoltage radiotherapy. While deep-lying tumors
require much higher energy levels with greater penetration power, and investigations
carried out in megavoltage energy range show contradictory results.
Objective: In this study, we quantitatively assess and compare dose enhancement
factors (DEFs) obtained through AuNPs under radiation of Cobalt-60 source
(1.25MeV) versus Iridium-192 source (380 KeV) using MAGAT gel dosimeter.
Material and Methods: MAGAT polymer gel in both pure and combined
with 0.2 mM AuNPs was synthesized. In order to quantify the effect of energy on
DEF, irradiation was carried out by Co-60 external radiotherapy and Ir-192 internal
radiotherapy. Finally, readings of irradiated and non-irradiated gels were performed
by MR imaging.
Results: The radiation-induced R2 (1/T2) changes of the gel tubes doped with
AuNPs compared to control samples, upon irradiation of beams released by Ir-192
source showed a significant dose enhancement (15.31% ±0.30) relative to the Co-60
external radiotherapy (5.85% ±0.14).
Conclusion: This preliminary study suggests the feasibility of using AuNPs in
radiation therapy (RT), especially in low-energy sources of brachytherapy. In addition,
MAGAT polymer gel, as a powerful dosimeter, could be used for 3D visualization
of radiation dose distribution of AuNPs in radiotherapy.
Keywords :
Nanotechnology , Gel Dosimetry , External Radiotherapy , Dose Enhancer , Brachytherapy
Journal title :
Journal of Biomedical Physics and Engineering