Title of article
High Power Laser and Photobiomodulation in Oral Surgery: Case Report
Author/Authors
Gomes Lúcio de Araújo, Júlia Department of Dentistry I - Federal University of Maranhão - Av. Dos Portugueses - 1966 - Bacanga - 65080-805 - São Luis - MA, Brazil , Michele dos Santos Araújo, Erika Department of Operative Dentistry - School of Dentistry - University of São Paulo (USP) - São Paulo - SP, Brazil , Cristina Nogueira Rodrigues, Fernanda Department of Operative Dentistry - School of Dentistry - University of São Paulo (USP) - São Paulo - SP, Brazil , Aurélio Benini Paschoal, Marco PUC Minas University - R. Dom José Gaspar - 804 - Coração Eucarístico - 30535-000 - Belo Horizonte - MG, Brazil , Dias Neves Lago, Andréa Department of Dentistry I - Federal University of Maranhão - Av. Dos Portugueses - 1966 - Bacanga - 65080-805 - São Luis - MA, Brazil
Pages
4
From page
75
To page
78
Abstract
Introduction: The labial frenum is a fold of mucous membrane that attaches the lip and the cheek to the alveolar mucosa, the gingiva, and the underlying periosteum. In some cases, its presence can cause a midline diastema, periodontal diseases related to food impaction, or retention of biofilm, among others. In such cases, lip frenectomy is indicated as treatment, which can be performed with a scalpel (conventional method), an electric scalpel, or a surgical laser.
Objective: To show a clinical case performed at Laser Extension Project in Dentistry, Federal University of Maranhao grounded in a literature review.
Case Presentation: A laser frenectomy was performed on a female patient, aged 20, who had a diastema between the upper central incisors and an indication for frenum removal. The high-power diode laser is excellent for procedures in soft tissue because its wavelength is well absorbed by hemoglobin and other pigments; its use also allows a reduction in the amount of anesthetic and medicines used. The parameters used were 2 W, in a continuous mode, 808 nm infrared emission; with delivery of the beam through optical fiber 300 ƒÊM; energy of 120 J; 20 pps.
Conclusion: the high power diode laser allowed a satisfactory result, the procedure was safe, the technique was a simple one and of reduced clinical time, as mentioned in the literature. It is worth noting that the technique is dependent on the skill of the professional performing it.
Keywords
Diode lasers , Labial frenum , Periodontics