Title of article
Ibuprofen Removal from a Pharmaceutical Wastewater using Electro-Fenton Process: An Efficient Technique
Author/Authors
Davarnejad ، R. Department of Chemical Engineering - Faculty of Engineering - Arak University , Zangene ، K. Department of Chemical Engineering - Faculty of Engineering - Arak University , Fazlali ، A. R. Department of Chemical Engineering - Faculty of Engineering - Arak University , Behfar ، R. Department of Chemical Engineering - Faculty of Engineering - Arak University
From page
1639
To page
1646
Abstract
The aim of this research is to evaluate the effective parameters such as pH, current density (mA/cm²), H2O2/Fe^2+ molar ratio, volume ratio of H2O2 to pharmaceutical wastewater (PhW) (ml/l) and reaction time (min) on the electro-Fenton process for the ibuprofen (as a pharmaceutical waste in water) removal. Since a synthetic wastewater with the same concentration of ibuprofen in a real pharmaceutical wastewater (400 ppm) was chosen in this research, the sample was tested in terms of the chemical oxygen demand (COD). The parameters were statistically optimized under response surface mythology (RSM). The software was also applied to minimize the number of runs. The optimum conditions for 98.29% COD removal experimentally were at pH of 2.43, current density of 23.08 mA/cm², H2O2/Fe^2+ molar ratio of 2.69, volume ratio of H2O2/PhW of 1.84 ml/l and reaction time of 28.08 min.
Keywords
COD , Electro , Fenton , Pharmaceutical Wastewater , Treatment
Journal title
International Journal of Engineering
Record number
2502507
Link To Document