Title of article :
Aortic Pseudoaneurysm in an Unusual Site: Difficult Diagnosis by Echocardiography
Author/Authors :
Hosseinsabet, Ali Tehran University of Medical Sciences, Tehran , Aghagani, Hasan Tehran University of Medical Sciences, Tehran , Forozannia, Khalil Tehran University of Medical Sciences, Tehran , Yaminisaharif, Ahmad Tehran University of Medical Sciences, Tehran
Abstract :
A 54-year-old woman was admitted to our hospital with a fever of 1 week’s duration and a distal embolic event 4
days previously in the second and third digits of her right hand. She had a history of aortic valve replacement (STj#19) 2
months earlier as well as mitral valve replacement (STj#26) and tricuspid valve repair 10 years before. Lab data showed an
increased white blood cell count and an elevated erythrocyte sedimentation rate. Blood culture was positive only in 1 round
with Pseudomonas aeruginosa growth, which was not compatible with the patient’s good general condition. Transthoracic
and transesophageal echocardiography, abdominal sonography, and computed tomography (CT) scan of the right hand
were unremarkable. The patient was treated for infectious endocarditis with antibiotics for 6 weeks and then discharged.
On follow-up transthoracic echocardiography, 1 month after discharge, an echo-free space in the posterolateral wall of the
ascending aorta was detected. The second transesophageal echocardiography was highly suggestive of a pseudoaneurysm in
the ascending aorta (Figure 1A & Video 1), which was subsequently confirmed by a CT angiography of the ascending aorta
(Figure 2). For a better evaluation, aortography was done and it revealed a pseudoaneurysm in the posterolateral wall of the
ascending aorta (Figure 3 & Video 2). A review of the previous transthoracic and transesophageal echocardiography images
demonstrated that this pseudoaneurysm had been missed because it was filled with a thrombosis (Figure 1B & Video 3). The
ascending aorta was normal in aortography before the second surgical operation. It appears that the most probable scenario was
thrombosis formation in an iatrogenic aortic pseudoaneurysm at an unusual site, causing such presentations. The thrombosis
was resolved with meticulous anticoagulation, leading to the clarification of the pseudoaneurysm. The administration of an
anticoagulant was obligatory in this patient because of the presence of 2 mechanical valves. Nevertheless, this administration
could lead to catastrophic events such as a ruptured ascending aorta, so the early detection of this complication may reduce
the risk to the patient and confer an appropriate treatment. We repaired our patient’s pseudoaneurysm via surgery, and she
was discharged in good physical condition. The development of an aortic pseudoaneurysm is an uncommon complication of
open-heart surgery, and it usually forms in the anterior wall; nonetheless, its formation in the posterior wall is rare and can
be due to the deep cannulation of the ascending aorta during surgery. The presence of this complication should, therefore, be
kept in mind by any cardiologist who encounters a patient with an embolic event and previous cardiac surgery.
Keywords :
Aorta , Aneurysm , false , Echocardiography , Diagnosis
Journal title :