• Title of article

    Hybrid Z-Source DC-DC Converter with ZVZCS and Power Transformer Resetting: Design, Modeling, and Fabrication

  • Author/Authors

    Torkaman, H the Faculty of Electrical Engineering - Shahid Beheshti University, A.C., Tehran, Iran , Hemmati, T the Faculty of Electrical Engineering - Shahid Beheshti University, A.C., Tehran, Iran

  • Pages
    10
  • From page
    49
  • To page
    58
  • Abstract
    This paper introduces a novel two transistors forward topology employing a z-source to achieve ZVZCS and power transformer resetting for various applications. Comparing with the forward converter, this topology has the advantage of displaying ZCS condition with an added Z-Source and no additional switches when the switches turn on, and that ZVS condition happens when the switches turn off. Duty cycle of the topology can exceed 50 percent. As a result, these converters are suitable for applications with high efficiency. In this paper, structure and properties of the topology will be discussed in details. Then the design principles will be presented. Finally, the benefits aforementioned will be approved in practice through a simple forward converter.
  • Keywords
    Zero Voltage Switching (ZVS) , Forward DC-DC Converter. , Zero Current Switching (ZCS) , Z-Source Converters
  • Journal title
    Iranian Journal of Electrical and Electronic Engineering(IJEEE)
  • Serial Year
    2018
  • Record number