• Title of article

    Water treatment by the AC gliding arc air plasma

  • Author/Authors

    Gharagozalian, Mehrnaz Biotechnology Lab - Plasma Physics Research Center - Science and Research Branch - Islamic Azad University, Tehran , Dorranian, Davoud Biotechnology Lab - Plasma Physics Research Center - Science and Research Branch - Islamic Azad University, Tehran , Ghoranneviss, Mahmood Biotechnology Lab - Plasma Physics Research Center - Science and Research Branch - Islamic Azad University, Tehran

  • Pages
    10
  • From page
    171
  • To page
    180
  • Abstract
    In this study, the effects of gliding arc (G Arc) plasma system on the treatment of water have been investigated experimentally. An AC power supply of 15 kV potential difference at 50 Hz frequency was employed to generate plasma. Plasma density and temperature were measured using spectroscopic method. The water was contaminated with staphylococcus aureus (Gram-positive) and salmonella bacteria (Gram-negative), and Penicillium (mold fungus) individually. pH, hydrogen peroxide, and nitride contents of treated water were measured after plasma treatment. Decontamination of treated water was determined using colony counting method. Results indicate that G Arc plasma is a powerful and green tool to decontaminate water without producing any byproducts.
  • Keywords
    G Arc discharge system , Removing bacteria , Complete sterilization , Spectroscopy , Salmonella , Penicillium (mold fungus) , staphylococcus aureus
  • Journal title
    Journal of Theoretical and Applied Physics
  • Serial Year
    2017
  • Record number