Title of article :
Mid-term Results of First Experience in Sutureless Aortic Valve Replacement in Iran
Author/Authors :
Alizadeh Ghavidel, Alireza Heart Valve Disease Research Center - Rajaie Cardiovascular Medical and Research Center - Iran University of Medical Sciences, Tehran , Sadeghpour, Anita Echocardiography Research Center - Rajaie Cardiovascular Medical and Research Center - Iran University of Medical Sciences, Tehran , Totonchi, Ziae Cardiac Anesthesia Department - Rajaie Cardiovascular Medical and Research Center - Iran University of Medical Sciences, Tehran , Austin, Nicholas Iran University of Medical Sciences, Tehran , Aldairy, Alwaleed Cardiac Surgery Department - Rajaie Cardiovascular Medical and Research Center - Iran University of Medical Sciences, Tehran
Abstract :
Background: Although the TAVI technique has been widespread in Europe and America, concerns have emerged regarding the
associated complications, mainly paravalvular leakage, vascular complications, stroke, post-operative pacemaker implantation due
to complete AV block, optimal access sites, long-term valve durability, and economic sustainability, therefore controversy remains
about the ideal treatment of high-risk operable patients. Sutureless tissue valves like Perceval S may be a good option for these high
risk operable patients. We will present the clinical outcomes of first cases of Perceval S in Iranian patients.
Methods: From July 2015 to August 2016, 11 patients (8 male, 3 female) with severe aortic stenosis who were candidates for aortic
valve replacement were included in this study. The mean age of patients was 738 ranged from 65 to 86 years. The most common
presenting symptom was dyspnea and three of the patients had coronary artery disease in need for concomitant revascularization.
Preoperative peak gradient across the aortic valve ranged from 72 to 135mmHg(mean = 9725). All patients were followed up from
3 to 20 months with a median of 13 months.
Results: Dramatic reduction of trans-aortic peak gradients was seen in all patient (mean postoperative gradient = 298 mmHg).
Small degrees of transvalvular and paravalvular leakage were seen in intraoperative echocardiographies but only one patient had
small asymptomatic paravalvular leakage during midterm follow up. Two patients need for transient pace maker; however we had
no case of complete heart block. Mean post-operative mediastinal bleeding was 480150mLand no patient needed re-exploration
for bleeding or tamponade management. ICU stay time was 31.54 days, and there was no in-hospital mortality. All patients were
discharged in good status and there was no mortality during follow-up period.
Conclusions: Preliminary clinical results of the first experience was encouraging; however we need to continue the study with
more study volume, more follow up period and more high risk or complicated patients.
Keywords :
Sutureless AVR , Aortic Valve Stenosis , Perceval S , TAVI
Journal title :
Multidisciplinary Cardiovascular Annals