Dasari, B. V. Division of Surgery - Department of Transplantation - St James’s University Hospital - United Kingdom , Asthana, S. Division of Surgery - Department of Transplantation - St James’s University Hospital - United Kingdom , Ahmad, N. Division of Surgery - Department of Transplantation - St James’s University Hospital - United Kingdom
Pages :
2
From page :
171
To page :
172
Abstract :
Data from UK National Transplant database indicates that 0.8%–1% of the kidneys are discarded due to organ damage with a 7% reported incidence of injuries during recovery of kidneys, of which 4.8% were renal vascular injuries related to procurement [1]. Whilst vascular injuries (arterial and venous) could be dealt with various reconstructions and modified anastomotic techniques [2], these could potentially lead to complications such as stenosis and rarely, thrombosis. Renal artery stenosis (RAS) of the anastomosis may lead to deterioration of graft function, hypertension and graft failure.
Keywords :
Avoid Injury , the Renal Artery due to Inclusion of Superior , Mesenteric Artery Patch , during Organ Procurement