Title of article :
Stabilization Time of Refractive Errors and Astigmatism after Cataract Surgery Using Phacoemulsification and Foldable Intraocular Lens Implants
Author/Authors :
Sharifi, Ali Kerman University of Medical Sciences, Iran , Daryabari, Hashem Chemical Injures Research Center - Systems Biology and Poisonings Institues - Baqiyatallah University of Medical Sciences, Tehran, Iran , Shams, Majid Kerman University of Medical Sciences, Iran , Sharifi, Hamid School of Public Health - HIV/STI Surveillance Research Center and WHO Collaborating Center for HIV Surveillance - Kerman University of Medical Sciences, Iran
Abstract :
Purpose: To evaluate the stabilization time of astigmatism and refractive
errors after cataract surgery using phacoemulsification and foldable lens
implantation.
Patients and Methods: The present cross-sectional study was carried out
with convenience sampling method and included patients who underwent
cataract surgery using phacoemulsification and implantation of foldable
intraocular lens. The patients were evaluated and their data including
age, sex, uncorrected visual acuity, best corrected visual acuity, corneal
cylinder, cylinder axis, Sim K, and intra ocular pressure were recorded
prior to the surgery as well as in days 2, 3, 4, weeks 1, 2, 5 and day 75
post surgery.
Results: Eighty one eyes of 77 patients with mean age of 61.39 ± 10.9
years were evaluated. The mean follow up time was 60.5 ± 48.86 days.
The mean keratometry before surgery was 44.90 ± 1.85 diopters, while the
mean axial length, the mean intraocular pressure and the mean astigmatism
were 23.15 ± 1.98 mm, 14.01 ± 2.95 mmHg and 0.99 ± 1.10 diopters,
respectively. The mean postoperative keratometry at last visit was 45.34
± 1.80 diopters, and the mean intraocular pressure and astigmatism were,
12.46 ± 2.87 mmHg and 1.14 ± 0.96 diopters, respectively. The mean
time for refraction stabilization was 11.46 ± 11.40 days and the mean
stabilization time for astigmatism was 10.18 ± 11.34 days.
Conclusion: In the present study the mean stabilization time for refraction
and astigmatism after cataract surgery in an Iranian population using
phacoemulsification and foldable lens implantation was comparable with
previous studies.
Keywords :
Refractive errors , Astigmatism , Cataract , Surgery , Stabilization time
Journal title :
Journal of Ophthalmic and Optometric Sciences