• Title of article

    Can [F-18] fluorodeoxyglucose positron emission tomography replace sentinel lymph node biopsy for the detection of axillary metastases in patients with early-stage breast cancer?

  • Author/Authors

    GÖRGÜLÜ, Semih Gülhane Military Medical Academy - Department of General Surgery, TURKEY , CAN, Mehmet Fatih Gülhane Military Medical Academy - Department of General Surgery, TURKEY , HANÇERLIOGULLARI, Oguz Gülhane Military Medical Academy - Department of General Surgery, TURKEY , ARSLAN, Nuri Gülhane Military Medical Academy - Department of Nuclear Medicine, TURKEY , ÖZTÜRK, Erkan Gülhane Military Medical Academy - Department of General Surgery, TURKEY , ÖZTÜRK, Emel Ufuk University - Faculty of Medicine - Department of Nuclear Medicine, TURKEY , BALKAN, Müjdat Gülhane Military Medical Academy - Department of General Surgery, TURKEY , TUFAN, Turgut Gülhane Military Medical Academy - Department of General Surgery, TURKEY

  • From page
    17
  • To page
    23
  • Abstract
    Aim: To investigate the value of fluorodeoxyglucose positron emission tomography (FDG-PET) in detecting axillary involvement, and to compare its accuracy with sentinel lymph node biopsy (SLNB) in patients with clinically early-stage breast cancer. Materials and methods: Twenty-eight female patients with histologically-confirmed T1-2 breast cancer who were scheduled to have SLNB were included in the study. FDG-PET images were obtained 1-7 days prior to surgery with an intravenous injection of 370 MBq of FDG, while plasma glucose levels were maintained below 120 mg/dL. All the images were interpreted by 2 independent nuclear medicine specialists, who were blinded to the histological diagnoses. SLNB was performed in standard fashion with peri-tumoral injection of isosulphan blue dye. In all cases, a level I-II axillary dissection was performed following SLNB. Sentinel nodes were processed after formalin fixation; no frozen sections were used. Results: Thirteen (46%) patients were found to have axillary involvement. SLNB (an average of 2.3 LNs removed perpatient) demonstrated metastases in all 13 patients. The diagnostic accuracy of FDG-PET was as follows: true-positivein 4 out of 13 patients (overall sensitivity = 31%), false-negative in 1 patient with metastasis (overall specificity = 94%),positive predictive value = 80%, negative predictive value = 63%, and accuracy = 68%. Conclusion: FDG-PET appears to be significantly less accurate than SLNB at detecting axillary metastases. In patients with an axillary-positive PET scan, however, axillary lymph node dissection may be performed without prior SLNB.
  • Keywords
    Breast cancer , sentinel lymph node biopsy , positron emission tomography , axillary metastasis
  • Journal title
    Turkish Journal of Medical Sciences (TJMS)
  • Journal title
    Turkish Journal of Medical Sciences (TJMS)
  • Record number

    2529315