Title of article :
Influence of RC Element Wiri ng in Electri cal Cir cuit on Electromechanical Thermostat Contact Wear
Author/Authors :
HAAS, Peter Slovak University of Agriculture, Slovakهش , KADNÁR, Milan Slovak University of Agriculture, Slovakia , RUSNÁK, Juraj Slovak University of Agriculture, Slovakia , TÓTH, František Slovak University of Agriculture, Slovakia , NÓGLI, Dušan Slovak University of Agriculture, Slovakia
Abstract :
Contact wear caused by electric arc during electric contact make (cut-in) and break (cut-out) has the direct impact on the contact lifetime. The RC element wired parallelly to the contact will eliminate or reduce the arcing and subsequently extend the lifetime. Comparative tests of the two sets of identical Danfoss 077B electromechanical thermostats have been carried out. In the first batch, standard thermostats were tested. In the second batch, the same thermostat types, but with RC elements wired parallel to thermostats main contacts were tested. Measurement has not proven any improvement of the contact wear. Temperature drift and change of the critical dimension caused by contact wear were very similar in the both cases. Thus, the application of RC element is considered not reasonable measure for reduction of contact wear of electromechanical thermostats.
Keywords :
RC element , electric arc , electromechanical thermostat , contact system , contact wear , temperature drift , contact bounce
Journal title :
Acta Technologica Agriculturae
Journal title :
Acta Technologica Agriculturae