Title of article
Technical Note on Using Intraoperative Smartphone Applications to Adjust Cup Inclination Angle during Total Hip Arthroplasty (THA)
Author/Authors
Khalifa, Ahmed A. Qena University Hospital and Assiut University Hospital, Egypt , Bakr, Hatem M. Qena University Hospital and Assiut University Hospital, Egypt , Said, Elsayed Qena University Hospital and Assiut University Hospital, Egypt , Mahran, Mohammad A. Qena University Hospital and Assiut University Hospital, Egypt
Pages
5
From page
734
To page
738
Abstract
Acetabular cup optimum position is paramount for total hip arthroplasty (THA) good outcomes. Although controversial, Lewinnek proposed safe zone for cup placement still the most widely accepted target. Cup placement can be improved using specific anatomical landmarks, computer navigation system and handheld navigation devices. As using a smartphone on daily bases became popular among orthopedic surgeons, in this technical note, we describe how to use smartphone specific applications intraoperatively during total hip arthroplasty to adjust cup inclination angle, which we believe to be easy, cheap and beneficial for young less experienced surgeons.
Farsi abstract
فاقد چكيده فارسي
Keywords
Cup , Inclination , Smartphone , THA