• Title of article

    Sensitive and Selective Reversed-Phase High Performance Liquid Chromatographic-UV Spectrophotometric Determination of Dextromethorphan and its CYP2D6 Mediated Metabolite, Dextrorphan in Human Urine

  • Author/Authors

    Ebeshi, Benjamin U. Niger Delta University - Faculty of Pharmacy - Department of Pharmaceutical Medicinal Chemistry, Nigeria , Ebeshi, Benjamin U. Obafemi Awolowo University - Faculty of Pharmacy - Department of Pharmaceutical Chemistry, Nigeria , Obodozie, Obiageri O. National Institute for Pharmaceutical Research Development - Department of Medicinal Chemistry Quality Control, Nigeria , Bolaji, Oluseye O. Obafemi Awolowo University - Faculty of Pharmacy - Department of Pharmaceutical Chemistry, Nigeria

  • From page
    281
  • To page
    286
  • Abstract
    Purpose: To develop a simple, sensitive and selective method for the determination of dextromethorphan and its metabolite, dextrophan in human urine using reversed-phase high performance liquid chromatography with UV-spectrophotometric detection (RP-HPLC-UV). Methods: Pre-column sample clean-up was carried out by liquid-liquid extraction of the analytes with chloroform: isopropanol (70:30) solution after alkalization of 1000 μL sample and spiking of internal standard, morphine. The samples were chromatographed in a reversed-phase (C-18) ultra sphere silica (5μm particle size and 250 x 4.6 mm I.D). The mobile phase consisted of methanol: acetonitrile: 0.5% w/v ammonium acetate (10:10:80) adjusted to pH 2.8 with orthophosphoric acid and pumped through the column at 1ml/min flow rate. The analytical method was validated for accuracy and precision as well as the recovery of the analytes, dextromethorphan and its metabolite, dextrophan over the concentration range of 0.20 to 5.0μg/ml. Results: The standard curves were linear over the concentration range of 0.2 to 5.0μg/ml for dextromethorphan and dextrorphan. The regression coefficients (R^2) of the analytes were 0.99. The method was reproducible with coefficient of variation for the analytes being 10 %. Dextromethorphan was well resolved from its metabolite, dextrorphan and the internal standard, morphine. The limits of detection of dextromethorphan and dextrorphan were 50ng/ml and the recoveries and accuracies were greater than 85 and 90 %, respectively. Conclusion: The analytical assay method exhibits good precision and selectivity and it was applied to the analysis of dextromethorphan and dextrorphan in urine for the assessment of CYP2D6 activity.
  • Keywords
    Dextromethorphan , Dextrophan , Reversed , phase high performance liquid chromatography , CYP2D6 activity , Human urine
  • Journal title
    Tropical Journal of Pharmaceutical Research
  • Journal title
    Tropical Journal of Pharmaceutical Research
  • Record number

    2536446