• Title of article

    Intra- and Inter-Session Reliability of Methods for Measuring Reaction Time in Participants with and without Patellofemoral Pain Syndrome

  • Author/Authors

    Zeinalzadeh, Afsaneh Physiotherapy Clinic of Ghaem University Hospital, Mashhad, Iran , Nazary-Moghadam, Salman Physiotherapy Clinic of Ghaem University Hospital, Mashhad, Iran , Sayyed Hoseinian, Hadi Physiotherapy Clinic of Ghaem University Hospital, Mashhad, Iran , Ebrahimzadeh, Mohammad H. Physiotherapy Clinic of Ghaem University Hospital, Mashhad, Iran , Imani, Esmaeel Physiotherapy Clinic of Ghaem University Hospital, Mashhad, Iran , Karimpour, Samira Physiotherapy Clinic of Ghaem University Hospital, Mashhad, Iran

  • Pages
    8
  • From page
    102
  • To page
    109
  • Abstract
    Background: To evaluate the relative and absolute reliability of reaction time measuring methods during different conditions in participants with and without patellofemoral pain syndrome (PFPS). Methods: 30 patients with PFPS and 30 healthy controls were recruited in the present study. The upper extremity reaction time, upper extremity error rate, involved and non-involved lower extremity braking reaction times, and involved and non-involved knee extension reaction times were measured. Each condition was repeated three times, 2 sessions with a 5-7 days interval. The intra-session reliability was evaluated in three-trial (A), second- and third-trial (B) modes. In addition, the inter-session reliability was evaluated in mode A, mode B, and best score (C) mode. Results: The result of inter-session reliability of mode A showed that all measurements except upper extremity reaction time in PFPS group showed high to very high relative reliability (ICC: 0.74-0.94). In mode B, all measurements except non-involved knee extension reaction time in PFPS group showed high to very high relative reliability (ICC: 0.71-0.93). In mode C, all measurements showed high to very high relative reliability (ICC: 0.70-0.94) except upper extremity error rate and non-involved knee extension reaction time in PFPS group. The result of intra-session reliability showed that all measurements had high to very high relative reliability (ICC: 0.78-0.94) in mode A. In mode B, all measurements showed high to very high relative reliability (0.78-0.94). Conclusion: The braking time seems more reliable than other reaction time tasks. In addition, the results showed that mode A is more reliable than other modes. The newly designed package is a reliable tool to measure the knee extension reaction time in patients with knee musculoskeletal disorders.
  • Farsi abstract
    فاقد چكيده فارسي
  • Keywords
    Knee , Patellofemoral pain syndrome , Reaction time , Reliability
  • Journal title
    The Archives of Bone and Joint Surgery
  • Serial Year
    2021
  • Record number

    2536476