Abstract :
Shallow footings are subjected to lateral forces induced by earthquake movements, wind loads, water wave pressure, lateral earth pressure, and transmitting power cables. In some structures such as water front structure, earth retaining structure and transmitting power structures, the lateral forces acting on the footings may be dominant. There has been little work studying the performance of skirted footings subjected to lateral loads. Twelve loading tests were performed on small scale circular skirted footing to shed some light on the performance of skirted footings when subjected to lateral loads. The effects of skirt length and the relative density of sand on the performance of the footing were investigated through laboratory testing program. Also a comparative experimental study between ultimate horizontal loads attained by skirted and unskirted footings with the same properties was conducted. From the accomplished laboratory tests it was found that the skirts changed the failure mode of circular shallow footings from sliding mechanism into rotational mechanism. Also the skirts attached to footings increased appreciably the ultimate horizontal capacity of shallow footings.
Keywords :
Skirted footings , Relative density , Bearing capacity ratio