Title of article :
Evaluation of Particulate Emission from a Palm Oil Mill Boiler
Author/Authors :
RASHID, M. Malaysia-Japan International Institute of Technology - Air Resources Research Laboratory, Malaysia , CHONG, W.C. Malaysia-Japan International Institute of Technology - Air Resources Research Laboratory, Malaysia , RAMLI, M. Universiti Teknologi Malaysia - Faculty of Chemical Engineering, Malaysia , ZAINURA, Z.N. Universiti Teknologi Malaysia - Faculty of Chemical Engineering, Malaysia , NORRUWAIDA, J. Malaysia-Japan International Institute of Technology - Air Resources Research Laboratory, Malaysia
From page :
1289
To page :
1292
Abstract :
A study to investigate the particulate emission from a boiler of a palm oil mill plant equipped with a multi-cyclones particulate arrestor was performed and reported in this paper. The particulate emission concentration was measured at the outlet of an 8000 kg steam/h capacity water-tube typed boiler of a palm oil mill plant processing 27000 kg/h of fresh fruit bunch (FFB). The particulate sample was collected iso-kinetically using the USEPA method 5 sampling train through a sampling port made at the duct of the exiting flue gas between the boiler and a multi-cyclones unit. The results showed that the particulate emission rates exiting the boiler varied from 8.51 g/s to 126 g/s with an average of 44.3±31.6 g/s. In terms of concentration, the average particulate emission concentration exiting the boiler was 7.75±4.71 g/Nm³ (corrected to 7% oxygen concentration), ranging from 1.50 to 17.7 g/Nm³ (@7% O2) of the flue gas during the measurement. Based on the 27000 kg/h FFB processed, 6000 kg/h fiber and shell (F S) burned and the capacity of the boiler of 8000 kg steam/h, the calculated particulate emission factor was 5.91±4.21 g particulate/kg FFB processed, 26.6±18.9 g particulate/kg F S burned and 19.9±14.2 g particulate/kg boiler capacity, respectively. Based on the finding, in order to comply with the emission limits of 0.4 g/Nm³, the required collection efficiency of any given particulate pollution control system to consider for the mill will be between 73 and 98%, which is not easily achievable with the existing multi-cyclones unit.
Keywords :
Air pollution , carbon soot , emission factor , multi , cyclone , palm oil mill
Record number :
2555736
Link To Document :
بازگشت