Title of article :
DETERMINATION OF AVOIDABLE & UNAVIODABLE EXERGY DESTRUCTIONS OF FURNACE- AIR PREHEATER COUPLED SYSTEM IN A PETROCHEMICAL PLANT
Author/Authors :
Sert, Selay Engineering Faculty Izmir - Ege University, Turkey , Balkan, Firuz Engineering Faculty Izmir - Ege University, Turkey
Abstract :
This study was performed with the intention of giving a deeper insight about the thermodynamic effectiveness of a thermal system. In this study, a fired heater (or furnace) existing in a petrochemical plant located in Aliağa, İzmir, Turkey were investigated from both first and second law point of view to
identify the true magnitude of thermodynamic inefficiencies and reveal the true potential improvements for the system components. Hence, apart from the classical energy analysis, both conventional and advanced exergy analysis were applied to the system. The major source of inefficiencies within the system
was enlightened by determining the exergy destructions and recommendation for possible modifications for improving thermodynamic efficiencies were stated. For each system component, amount of exergy destructions were determined and exergy efficiencies were calculated as 40.9% and 39.3% for fired heater (FH) and air preheater(APH), respectively in conventional exergy analysis. Besides, applying the advanced exergy analysis method it was seen that exergy efficiencies can be increased up to 52.4% and 85.8%, respectively.
Keywords :
energy , exergy , advanced exergy , air preheater , furnace
Journal title :
Journal of Thermal Engineering