Title of article :
Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation
Author/Authors :
Peirovifar, EJ Ali tabriz university of medical sciences - Faculty of Medicine - Department of Anesthesiology, Anesthesiology Research Team, ايران , Eydi, Mahmood tabriz university of medical sciences - Faculty of Medicine - Department of Anesthesiology, Anesthesiology Research Team, ايران , Mirinejhad, Mir Mousa tabriz university of medical sciences - Faculty of Medicine - Department of Anesthesiology, Anesthesiology Research Team, ايران , Mahmoodpoor, Ata tabriz university of medical sciences - Faculty of Medicine - Department of Anesthesiology, Anesthesiology Research Team, ايران , Mohammadi, Afsaneh tabriz university of medical sciences - Faculty of Medicine - Department of Anesthesiology, Anesthesiology Research Team, ايران , Golzari, Samad EJ tabriz university of medical sciences - Physical Medicine and Rehabilitation Research Center - Students’ Research Committee, Anesthesiology Research Team, ايران
From page :
601
To page :
605
Abstract :
Objective: To compare the postoperative complications between Laryngeal Mask Airway (LMA) and endotracheal tube (ETT) during low-flow anesthesia with controlled ventilation. Methodology: Eighty adult Patients with ASA class I or II were randomly allocated into two forty-patient groups (ETT or LMA). Cuff pressure was monitored during anesthesia. After high uptake period, fresh gas flow (FGF) was decreased to 1 lit/min and isoflurane set to 1%. Monitoring during anesthesia included non-invasive blood pressure, ECG, ETCO2 and pulse oximetry. System leakage ( 100 ml/min), rebreathing and any attempt to increase FGF to overcome the leak were monitored during anesthesia. Later, patients were extubated and transferred to Post Anesthesia Care Unit (PACU). In PACU, the incidence of sore throat, cough, difficulty in swallowing and shivering was monitored for all patients. Results: Leakage was observed in two and three cases in ETT and LMA groups respectively (P 0.05). Postoperative cough, sore throat and difficulty in swallowing were significantly less in LMA than ETT group. No significant difference was observed regarding ETCo2 values between 2 groups. Conclusion: If careful measures regarding insertion techniques, correct LMA position and routine monitoring of LMA cuff pressure are taken, LMA can be used as a safe alternative with lower incidence of post operation complication compared with ETT during low-flow controlled anesthesia with modern anesthetic machines.
Keywords :
Laryngeal Mask Aiway , Endotracheal Tube , Low , flow anesthesia , Complications , Controlled ventilation.
Journal title :
Pakistan Journal of Medical Sciences
Journal title :
Pakistan Journal of Medical Sciences
Record number :
2576117
Link To Document :
بازگشت