Title of article :
Analysis of discharge parameters and optimization study of coaxial DBDs for efficient excimer light sources
Author/Authors :
Pal, Udit Narayan Council of Scientific and Industrial Research-Central Electronics Engineering Research Institute (CSIR-CEERI) - Plasma Devices Group, Microwave Tubes Division, India , Gulati, Pooja Council of Scientific and Industrial Research-Central Electronics Engineering Research Institute (CSIR-CEERI) - Plasma Devices Group, Microwave Tubes Division, India , Kumar, Niraj Council of Scientific and Industrial Research-Central Electronics Engineering Research Institute (CSIR-CEERI) - Plasma Devices Group, Microwave Tubes Division, India , Kumar, Mahesh Council of Scientific and Industrial Research-Central Electronics Engineering Research Institute (CSIR-CEERI) - Plasma Devices Group, Microwave Tubes Division, India , Srivastava, Vishnu Council of Scientific and Industrial Research-Central Electronics Engineering Research Institute (CSIR-CEERI) - Plasma Devices Group, Microwave Tubes Division, India , Prakash, Ram Council of Scientific and Industrial Research-Central Electronics Engineering Research Institute (CSIR-CEERI) - Plasma Devices Group, Microwave Tubes Division, India
From page :
1
To page :
8
Abstract :
In this work, a xenon-filled quartz coaxial dielectric barrier discharge (DBD) tube (ID 6 mm, OD 12 mm) at 400-mbar pressure has been studied at different operating conditions. High-frequency sinusoidal and unipolar pulse-like voltages are applied at the discharge electrodes for the generation of micro-discharge plasma. Visual images of the discharge and the electrical waveform confirm the diffused-type discharge. The mechanism that is involved in the ignition, development and extinction of DBDs is quantitatively explained by dynamic processes in the discharge. An equivalent electrical model representing the DBD phenomenon has also been used to validate the characteristic discharge parameters. The relative intensity analysis of the Xe continuum peak at wavelength 172 nm in the optical emission spectra of the vacuum ultraviolet region has been carried out for different operating conditions. Approximately three times increment in the radiation is observed in pulse excitation over sinusoidal excitation. It infers that the pulsed excitation of DBD sources is advantageous for excimer light sources.
Keywords :
Non , thermal plasma and non , equilibrium plasma , Dielectric barrier discharge (DBD) , Micro , discharges , Diffused discharge , Equivalent electrical circuit
Journal title :
Journal of Theoretical and Applied Physics
Journal title :
Journal of Theoretical and Applied Physics
Record number :
2578371
Link To Document :
بازگشت