Title of article
SUCCESSFUL LATE REPAIR OF A TRAUMATIC TRACHEOESOPHAGEAL FISTULA AFTER FOREIGN BODY INHALATION
Author/Authors
Hussen, Waleed Mustafa University of Baghdad - Medical City Teaching Hospital, College of Medicine - Department of Thoracic Vascular Surgery, Iraq
From page
177
To page
179
Abstract
Aim: Is to report a case of Traumatic trachea-esophageal fistula complicating long standing inhaled foreign body, which is rarely reported in the literatures and to compare it with others studies reporting similar case. Methods: The details, the presentation, both clinical and radiological findings. Bronchoscopic esophagoscopic appearances of such case are presented. Results: The diagnosis was verified with contrast study and endoscopic findings .The corrective surgery was done through right thoracotomy where mobilization of the esophagus and trachea was made and the fistula was clearly demonstrate and divided and both sides were repaired with a smooth post operative outcome . Conclusion: Meticulous bronchscopy and safe operator with a careful follow up is mandatory to prevent such complication and once it happened, surgery only offers the best chance of cure
Keywords
Contrast study , Bronchoscopy , Esophagoscopy
Journal title
The Egyptian Journal of Surgery
Journal title
The Egyptian Journal of Surgery
Record number
2588607