Title of article :
The Twelve-Month Outcome of Biolimus Eluting Stent with Biodegradable Polymer Compared With an Everolimus Eluting Stent with Durable Polymer
Author/Authors :
Separham, Ahmad tabriz university of medical sciences - Shahid Madani Heart Hospital - Cardiovascular Research Center, ايران , Sohrabi, Bahram tabriz university of medical sciences - Shahid Madani Heart Hospital - Cardiovascular Research Center, ايران , Aslanabadi, Naser tabriz university of medical sciences - Shahid Madani Heart Hospital - Cardiovascular Research Center, ايران , Ghaffari, Samad tabriz university of medical sciences - Shahid Madani Heart Hospital - Cardiovascular Research Center, ايران
Abstract :
Introduction Drugeluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimuseluting stent (with biodegradable polymer) with an everolimuseluting stent (with durable polymer) one.Methods: We performed a randomized trial to compare the two types of stents. Two hundred patients undergoing PCI for de novo lesions were randomly assigned 1:1 to treatment with either biolimuseluting (BioMatrix) or everolimuseluting (Xience V) stent. The primary endpoint was a composite of cardiac death, myocardial infarction, and clinically driven target vessel revascularization within 12 months. Results: Demographics, clin-ical, and lesion characteristic were comparable between two groups. The 30-day major adverse cardiac event (MACE) rate was 2% in BioMatrix group versus 0% in Xience group (p 0.05). After 12 months, the rates of cardiac death (0% in both groups), MI (2% versus 0%, p=0.49) and clinically –driven target vessel revascularization (0% in both groups) were similar for BioMatrix and Xience. No stent thrombosis was reported at 1, 6, 9 or 12 months after intervention in either group. Conclusion: BES (Biolimus-eluting stent) with biodegradable polymer and EES (Everolimus-eluting stent) with durable polymer appear similar with respect to MACE and stent thrombosis in this patient population. Many studies with longer follow up are needed to define better the role of BES with bio-degradable polymer in treatment of coronary artery lesions.
Keywords :
Biolimus , Eluting Stent , Everolimus , Eluting Stent , Biodegradable Polymer , Coronary Artery Disease , Revascularization
Journal title :
Journal of Cardiovascular and Thoracic Research (JCVTR)
Journal title :
Journal of Cardiovascular and Thoracic Research (JCVTR)