Title of article
INVESTIGATION OF MODIFIED EJECTOR CYCLE ON RESIDENTIAL AIR CONDITIONER WITH ENVIRONMENTALLY BENIGN REFRIGERANT OF R290
Author/Authors
Sumeru, Kasni Department of Refrigeration & Air Conditioning, Bandung, Indonesia , Sukri, Mohamad Firdaus Efficient Energy Technology (GrEET) Research Group - Universiti Teknikal Malaysia Melaka, Melaka, Malaysia , Pratikto, Pratikto Department of Refrigeration & Air Conditioning, Bandung, Indonesia , Badarudin, Apip Department of Refrigeration & Air Conditioning, Bandung, Indonesia
Pages
16
From page
297
To page
312
Abstract
This paper investigates a modified ejector cycle (MEC) to further enhance the COP improvement of residential air conditioner (A/C), as compared to the standard ejector cycle (SEC). This paper also presents numerical and experimental studies of the MEC. Numerical approach of MEC performances was evaluated by using SEC cycle that had been developed by many researchers. In the experimental study of MEC, three motive nozzle diameters of 0.9, 1.0 and 1.1 mm were utilized. In addition, environmentally friendly refrigerant of R290 (propane) was used as a working fluid. The modeling results of residential A/C with the cooling capacity of 2.5 kW showed higher COP improvements of MEC than SEC for all entrainment ratios of the ejector. There was no COP improvement for SEC at a low entrainment ratio, whereas there are always COP improvements for all entrainment ratios for MEC. In addition, the experimental results showed the highest COP improvement of 16.67% was achieved with the motive nozzle diameter of 1.1 mm.
Keywords
Air Conditioner , Ejector , R290 , Modified Ejector Cycle , Entrainment Ratio , COP Improvement
Journal title
Journal of Thermal Engineering
Serial Year
2020
Record number
2594210