Title of article :
Use of Tornus for a Lesion That is Easily Balloon Crossable but No Expandible Despite High Pressure
Author/Authors :
Temiz, Ahmet Rize Traning and Research Hospital - Cardiology Clinic, Turkey , Bostan, Mehmet Rize University - Faculty of Medicine - Department of Cardiology, Turkey
From page :
43
To page :
46
Abstract :
Coronary angiography (CAG) was performed on a 78-year-old female patient due to class III angina. A calcified critical obstruction was demonstrated in the right coronary artery (RCA). An attempt at percutaneous transluminal coronary angioplasty (PTCA) failed to dilatate the lesion despite high balloon pressure. In a second attempt the lesion was dilatated with the balloon after implementing a tornus penetration device, and then a stent was implanted. A dissection occurred after the stent implantation and it was treated with another stent. The treatment of lesions that cannot be dilatated using conventional PTCA techniques and the role of the tornus penetration device in such cases are discussed.
Keywords :
Percutaneous transluminal coronary angioplasty , coronary artery stenosis , calcification
Journal title :
Erciyes Medical Journal
Journal title :
Erciyes Medical Journal
Record number :
2597337
Link To Document :
بازگشت