Title of article :
Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report
Author/Authors :
PX, Hwang Department of Orthopaedics - Universiti Sains Malaysia - Kubang Kerian - Malaysia , NA, Anuwar Department of Orthopaedics - Universiti Sains Malaysia - Kubang Kerian - Malaysia , YC, Khaw Department of Orthopaedics - Universiti Sains Malaysia - Kubang Kerian - Malaysia , D, Hadizie Department of Orthopaedics - Universiti Sains Malaysia - Kubang Kerian - Malaysia
Pages :
4
From page :
74
To page :
77
Abstract :
Coronal malalignment due to malrotated trochanteric nail placement in femoral fracture fixation has never been reported. We present a case of a femoral segmental fracture fixed with a trochanteric nail, with a malrotated placement resulting in a valgus malaligned nail and femur, associated with a rotational malalignment. Knowledge of the modern nail design with proper intra-operative precautions, would avoid this underestimated technical error.
Keywords :
valgus , nail , malalignment , Malunio‎n , malrotated
Journal title :
Malaysian Orthopaedic Journal
Serial Year :
2020
Full Text URL :
Record number :
2604972
Link To Document :
بازگشت