Title of article :
Prospective Trial to Compare Direct and Indirect Laryngoscopy Using C-MAC PMD with Macintosh Blade and D-BladeD in a Simulated Difficult Airway
Author/Authors :
Jürgen Raimann, Florian Department of Anesthesiology - Intensive Care Medicine and Pain Terapy - University Hospital Frankfurt - Teodor-Stern Kai 7 - 60590 Frankfurt - Germany , Edmund Dietze, Philipp Department of Anesthesiology - Intensive Care Medicine and Pain Terapy - University Hospital Frankfurt - Teodor-Stern Kai 7 - 60590 Frankfurt - Germany , Elizabeth Cuca, Colleen Department of Anesthesiology - Intensive Care Medicine and Pain Terapy - University Hospital Frankfurt - Teodor-Stern Kai 7 - 60590 Frankfurt - Germany , Meininger, Dirk Main-Kinzig-Clinic - Department of Anesthesia - Intensive Care Medicine and Pain Terapy - Herzbachweg 14 - 63571 Gelnhausen - Germany , Kessler, Paul Clinic of Anesthesiology - Intensive Care and Pain Terapy - Orthopedic Clinic Friedrichsheim - Marienburgstraße 2 - 60528 Frankfurt am Main, Germany , Byhahn, Christian Evangelical Hospital Oldenburg - Department of Anesthesia - Intensive Care Medicine and Pain Terapy - Steinweg 13-17, 26122 Oldenburg - Germany , Gill-Schuster, Daniel Department of Anesthesiology - Intensive Care Medicine and Pain Terapy - University Hospital Frankfurt - Teodor-Stern Kai 7 - 60590 Frankfurt - Germany , Zacharowski, Kai Department of Anesthesiology - Intensive Care Medicine and Pain Terapy - University Hospital Frankfurt - Teodor-Stern Kai 7 - 60590 Frankfurt - Germany , Mutlak, Haitham Department of Anesthesiology - Intensive Care Medicine and Pain Terapy - University Hospital Frankfurt - Teodor-Stern Kai 7 - 60590 Frankfurt - Germany
Pages :
8
From page :
1
To page :
8
Abstract :
Objective. Evaluation of C-MAC PM in combination with a standard Macintosh blade size 3 in direct and indirect laryngoscopy and D-Blade in indirect laryngoscopy in a simulated difcult airway. Primary outcome was defned as the best view of the glottic structures. Secondary endpoints were subjective evaluation and assessment of the intubation process. Methods. Prospective monocentric, observational study on 48 adult patients without predictors for difcult laryngoscopy/tracheal intubation undergoing orthopedic surgery. Every participant preoperatively received a cervical collar to simulate a difcult airway. Direct and indirect laryngoscopy w/o the BURP maneuver with a standard Macintosh blade and indirect laryngoscopy w/o the BURP maneuver using D-Blade were performed to evaluate if blade geometry and the BURP maneuver improve the glottic view as measured by the Cormack-Lehane score. Results. Using a C-MAC PM laryngoscope, D-Blade yielded improved glottic views compared with the Macintosh blade used with either the direct or indirect technique. Changing from direct laryngoscopy using a Macintosh blade to indirect videolaryngoscopy using C-MAC PM with D-Blade improved the Cormack-Lehane score from IIb, III, or IV to I or II in 31 cases. Conclusion. Te combination of C-MAC PM and D-Blade signifcantly enhances the view of the glottis compared to direct laryngoscopy with a Macintosh blade in patients with a simulated difcult airway. Trial Registration Number. Tis trial is registered under number NCT03403946.
Keywords :
C-MAC PM , Prospective Trial , Laryngoscopy , Macintosh Blade , D-Blade , Simulated Difficult Airway
Journal title :
Emergency Medicine International
Serial Year :
2019
Full Text URL :
Record number :
2606612
Link To Document :
بازگشت