Title of article :
Accuracy and Precision Evaluation of International Standard Spherical Model by Digital Dental Scanners
Author/Authors :
Jiang, Heng Bo Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Cai, Hong Xin Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Jia, Qi Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Shi, HaoYu Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Jiang, Yujie Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Xue, Jingnan Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Chen, ChunXu Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Gong, Haotian Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Liu, Jie Stomatological Materials Laboratory - School of Stomatology - Shandong First Medical University & Shandong Academy ofMedical Sciences - Tai’an - Shandong , China , Lee, Eui-Seok Department of Oral and Maxillofacial Surgery - Graduate School of Clinical Dentistry - Korea University - Seoul , Republic of Korea
Pages :
6
From page :
1
To page :
6
Abstract :
With the popularization of digital technology and the exposure of traditional technology’s defects, computer-aided design andcomputer-aided manufacturing (CAD/CAM) has been widely used in thefield of dentistry. and the accuracy of the scanningsystem determines the ultimate accuracy of the prosthesis, which is a very important part of CAD/CAM, so we decided toevaluate the accuracy of the intraoral and extraoral scanners. In this study, we selected the sphere model as the scanning objectand obtained thefinal result through data analysis and 3Dfitting. In terms of trueness and precision, the scanner of SHININGwas significantly different from that of others; however, there was no significant difference between TRIOS and CEREC.SHINING showed the lowest level of accuracy, with CEREC slightly lower than TRIOS. The sphere model has also been provento be scanned successfully.
Keywords :
Accuracy , Precision Evaluation , International Standard Spherical Model , Digital Dental Scanners , CERE , CAD/CAM
Journal title :
Scanning
Serial Year :
2020
Full Text URL :
Record number :
2613118
Link To Document :
بازگشت