• Title of article

    Tibial and fibular nerves evaluation using intraoperative electromyography in rats

  • Author/Authors

    Nepomuceno, André Coelho Department of Plastic Surgery and Microsurgery - Medical School - Universidade de São Paulo (USP), Brazil , Politani, Elisa Landucci Medical School - USP, Sao Paulo-SP, Brazil , Silva, Eduardo Guandelini da Medical School - USP, Sao Paulo-SP, Brazil , Salomone, Raquel Department of Otorhinolaryngology - USP, Sao Paulo-SP, Brazil , Longo, Marco Vinicius Losso Department of Plastic Surgery and Microsurgery - Medical School - USP, Sao Paulo-SP, Brazil , Salles, Alessandra Grassi Department of Plastic Surgery and Microsurgery - Medical School - USP, Sao Paulo-SP, Brazil , Faria, José Carlos Marques de Department of Plastic Surgery and Microsurgery - Medical School - USP, Sao Paulo-SP, Brazil , Gemperli, Rolf Department of Plastic Surgery and Microsurgery - Medical School - USP, Sao Paulo-SP, Brazil

  • Pages
    7
  • From page
    542
  • To page
    548
  • Abstract
    PURPOSE: To evaluate a new model of intraoperative electromyographic (EMG) assessment of the tibial and fibular nerves, and its respectives motor units in rats. METHODS: Eight Wistar rats underwent intraoperative EMG on both hind limbs at two different moments: week 0 and week 12. Supramaximal electrical stimulation applied on sciatic nerve, and compound muscle action potential recorded on the gastrocnemius muscle (GM) and the extensor digitorum longus muscle (EDLM) through electrodes at specifics points. Motor function assessment was performaced through Walking Track Test. RESULTS: Exposing the muscles and nerves for examination did not alter tibial (p=0.918) or fibular (p=0.877) function between the evaluation moments. Electromyography of the GM, innervated by the tibial nerve, revealed similar amplitude (p=0.069) and latency (p=0.256) at week 0 and at 12 weeks, creating a standard of normality. Meanwhile, electromyography of the EDLM, innervated by the fibular nerve, showed significant differences between the amplitudes (p=0.003) and latencies (p=0.021) at the two different moments of observation. CONCLUSION: Intraoperative electromyography determined and quantified gastrocnemius muscle motor unit integrity, innervated by tibial nerve. Although this study was not useful to, objectively, assess extensor digitorum longus muscle motor unit, innervated by fibular nerve.
  • Keywords
    Electromyography , Tibial Nerve , Peroneal Nerve , Rats , Wistar
  • Journal title
    Acta Cirurgica Brasileira
  • Serial Year
    2016
  • Record number

    2615179