Title of article :
3D - Printed Patient Specific Instrumentation in Corrective Osteotomy of the Femur and Pelvis: A Review of the Literature
Author/Authors :
Mulpuri, Kishore Department of Orthopaedic Surgery - BC Children’s Hospital - Vancouver, Canad , Baraza, Njalalle Department of Orthopaedic Surgery - BC Children’s Hospital - Vancouver, Canad , Chapman, Chris Department of Surgery - Aga Khan University Hospital - Nairobi, Kenya , Zakani, Sima BC Children’s Hospital - Vancouver - BC, Canada
Abstract :
The paediatric patient population has considerable variation in anatomy. The use of Computed
Tomography (CT)-based digital models to design three-dimensionally printed patient specific instrumentation (PSI)
has recently been applied for correction of deformity in orthopedic surgery. This review sought to determine the
existing application of this technology currently in use within paediatric orthopaedics, and assess the potential
benefits that this may provide to patients and surgeons.
Methods: A review was performed of MEDLINE, EMBASE, and CENTRAL for published literature, as well as Web of
Science and clinicaltrials.gov for grey literature. The search strategy revolved around the research question: “What is
the clinical impact of using 3D printed PSI for proximal femoral or pelvic osteotomy in paediatric orthopaedics?”
Two reviewers, using predetermined inclusion criteria, independently performed title and abstract review in order
to select articles for full text review. Data extracted included effect on operating time and intraoperative image use,
as well as osteotomy and screw positioning accuracy. Data were combined in a narrative synthesis; meta-analysis
was not performed given the diversity of study designs and interventions.
Results: In total, ten studies were included: six case control studies, three case series and a case report. Five studies
directly compared operating time using PSI to conventional techniques, with two showing a significant decrease in
the number of intraoperative images and operative time. Eight studies reported improved accuracy in executing
the surgical plan compared to conventional methods.
Conclusion: Compared to conventional methods of performing femoral or pelvic osteotomy, use of PSI has led to
improved accuracy and precision, decreased procedure times, and decreased intra-operative imaging requirements.
Additionally, the technology has become more cost effective and accessible since its initial inception and use.
Keywords :
Patient specific instrumentation , 3D printing , Orthopaedic surgery , Femoral osteotomy , Pelvic osteotomy
Journal title :