Title of article :
Measurement of mean systemic filling pressure after severe hemorrhagic shock in swine anesthetized with propofol-based total intravenous anesthesia: implications for vasopressor-free resuscitation
Author/Authors :
Chalkias, Athanasios Department of Anesthesiology - Faculty of Medicine - School of Health Sciences - University of Thessaly - Larissa, Cyprus , Koutsovasilis, Anastasios Department of Internal Medicine - Nikaia General Hospital - Nikaia, Cyprus , Eleni Laou Department of Anesthesiology - Faculty of Medicine - School of Health Sciences - University of Thessaly - Larissa, Cyprus , Papalois, Apostolos graduate , Xanthos, Theodoros European University Cyprus - School of Medicine - Nicosia, Cyprus
Abstract :
Background: Mean systemic filling pressure (Pmsf) is a quantitative measurement of a patient’s volume status and represents the tone of the venous reservoir. The aim of this study
was to estimate Pmsf after severe hemorrhagic shock and cardiac arrest in swine anesthetized with propofol-based total intravenous anesthesia, as well as to evaluate Pmsf’s association with vasopressor-free resuscitation.
Methods: Ten healthy Landrace/Large-White piglets aged 10–12 weeks with average weight
20±1 kg were used in this study. The protocol was divided into four distinct phases: stabilization, hemorrhagic, cardiac arrest, and resuscitation phases. We measured Pmsf at 5–7.5 seconds after the onset of cardiac arrest and then every 10 seconds until 1 minute postcardiac
arrest. During resuscitation, lactated Ringers was infused at a rate that aimed for a mean right
atrial pressure of ≤4 mm Hg. No vasopressors were used.
Results: The mean volume of blood removed was 860±20 ml (blood loss, ~61%) and the
bleeding time was 43.2±2 minutes while all animals developed pulseless electrical activity.
Mean Pmsf was 4.09±1.22 mm Hg, and no significant differences in Pmsf were found until 1
minute postcardiac arrest (4.20±0.22 mm Hg at 5–7.5 seconds and 3.72±0.23 mm Hg at 55–
57.5 seconds; P=0.102). All animals achieved return of spontaneous circulation (ROSC), with
mean time to ROSC being 6.1±1.7 minutes and mean administered volume being 394±20 ml.
Conclusions: For the first time, Pmsf was estimated after severe hemorrhagic shock. In this
study, Pmsf remained stable during the first minute post-arrest. All animals achieved ROSC
with goal-directed fluid resuscitation and no vasopressors.
Keywords :
anesthesia , hemodynamics , hemorrhagic shock , mean systemic filling pressure , resuscitation
Journal title :
Acute and Critical Care