MEMİŞOĞLU, Kaya Kocaeli University - Faculty of Medicine - Department of Orthopaedics and Traumatology, Turkey , MÜEZZİNOĞLU, Sefa Kocaeli University - Faculty of Medicine - Department of Orthopedics and Traumatology, Turkey , KESEMENLİ, Cumhur Cevdet Kocaeli University - Faculty of Medicine - Department of Orthopedics and Traumatology, Turkey
From page :
410
To page :
412
Abstract :
The Gunston polycentric knee arthroplasty, first designed and performed by Frank Gunston in 1971, is the first prosthesis considering the natural knee biomechanics. Although the polycentric knee arthroplasty showed encouraging results to relieve pain and to preserve the preoperative range of motion and joint instability, the improvements in prosthesis design and arthroplasty technology rapidly made the polycentric knee prosthesis obsolete. Herein, we report a 58-year old male patient who had revision of the Gunston polycentric knee arthroplasty with total knee arthroplasty performed 32 years after the initial operation.
Keywords :
Arthroplasty , knee , polycentric knee , revision.