• Title of article

    Dimensional accuracy of 3 silicone dental impression materials

  • Author/Authors

    Hassan, A.K. Medical Services of Qatar Armed Forces, Qatar

  • From page
    632
  • To page
    636
  • Abstract
    This study was carried out to measure the dimensional changes in silicone impression material, which can affect the fitness of the prosthesis. Using both single and double mix techniques, 20 impression samples for each of 3 different proprietary silicones, Xantopren-H, President and Fulldent, were made. Selected measurements were made on the stone casts made from each impression. In all 3 cases, the single mix gave more accurate casts than the double mix technique. The Xantopren-H impressions had the most accurate dimensions.
  • Journal title
    Eastern Mediterranean Health Journal
  • Journal title
    Eastern Mediterranean Health Journal
  • Record number

    2638391