• Title of article

    A study of underfill morphology and filler content using scanning electron microscopy and thermogravimetric analyzer

  • Author/Authors

    AHMAD, I. Universiti Kebangsaan Malaysia - Faculty of Engineering, Malaysia , ENDUT, Z. Universiti Kebangsaan Malaysia - Faculty of Engineering, Malaysia , ZAHARIM, A. Universiti Kebangsaan Malaysia - Faculty of Engineering, Malaysia , SUKEMI, NORAZHAM MOHD Freescale Semiconductor, (M) Sdn. Bhd., No.2, Malaysia

  • From page
    44
  • To page
    48
  • Abstract
    The filler content of two type capillary underfill materials for flip chip packaging were studied using Thermogravimetric Analyzer (TGA) and Scanning Electron Microscopy (SEM). An epoxy based resin and cyanate ester based resin were sUbjected to TGA to determine the percentage of filler content and theirs morphology were studied using SEM. The results show that these two underfills materials have a very similar percentage of filler content which is around 70% and shows good morphology propeliies for capillary underfill application.
  • Keywords
    Flip chip , underfill , filler content , morphology , SEM , TGA
  • Journal title
    Journal of Sustainability Science and Management
  • Journal title
    Journal of Sustainability Science and Management
  • Record number

    2644759