Title of article :
Aortic Arch Replacement with Moderate Hypothermia and a Modified Three-PUMP Circuit
Author/Authors :
Vaijyanath, Prashant Dr. K. M. Cherian Heart Foundation, India , Sekar, Lavanya Dr. K. M. Cherian Heart Foundation, India , Thomas, Mary Smitha Dr. K. M. Cherian Heart Foundation, India
From page :
211
To page :
213
Abstract :
A strategy employing moderate hypothermia for the replacement of the aortic arch is proposed to avoid the complications of profound hypothermic circulatory arrest. Two patients underwent the complete replacement of the aortic arch using three pumps - for the brain, thoracoabdominal aorta, and heart, respectively. There were no complications and the patients were extubated uneventfully. The method preserved the auto-regulation of the cerebral blood flow without high vascular resistance.
Keywords :
Surgical procedures , operative • Aorta , thoracic • Cardiopulmonary bypass • Hypothermia • Cerebrovascular circulation
Journal title :
The Journal of Tehran University Heart Center (JTHC)
Journal title :
The Journal of Tehran University Heart Center (JTHC)
Record number :
2645465
Link To Document :
بازگشت