Fathi, Mohammad Department of Biomedical Engineering - Science and Research Branch - Islamic Azad University - Tehran, Iran , Setarehdan, Kamaledin Control and Intelligent Processing Center of Excellence - School of Electrical and Computer Engineering - College of Engineering - University of Tehran - Tehran, Iran , Nowshiravan Rahatabad, Fereidoon Department of Biomedical Engineering - Science and Research Branch - Islamic Azad University - Tehran, Iran , Jafarnia Dabanloo, Nader Department of Biomedical Engineering - Science and Research Branch - Islamic Azad University - Tehran, Iran
Pages :
10
From page :
226
To page :
235
Abstract :
Purpose: The artificial aperture imaging method owns a good contrast in the data recording and imaging process. However, this method is very time consuming that prevents its practical implementation. Materials and Methods: In this paper, the separated waveforms are sent by two elements together, instead of a single element, and the combination of the methods of independent component analysis and adaptive filtering both are used to extract different components in the received echoes. The obtained result illustrates that the imaging is performed in less time, and the computational complexity of this method is declined. Results: The proposed algorithm has been evaluated on two sets of simulated data and experimental data. The results indicate that the proposed method in the point phantom mode is only 1.5% worse in the resolution than the conventional artificial aperture method. Also, from the contrasting viewpoint, the proposed method has made the CR parameter worse by about 1.34dB than the conventional artificial aperture method. These adverse points of resolution and contrast in the proposed method are neglected than the conventional artificial aperture method because of a slight decrease in image quality than the artificial aperture method. Conclusion: However, the proposed method improves the computational complexity by 45% than the conventional artificial aperture method. As a result, it has brought the researchers closer to the practical implementation of artificial aperture imaging.
Keywords :
Medical Ultrasound Imaging , Computational Complexity , Artificial Aperture Method , Independent Component Analysis , Adaptive Filter
Journal title :
Frontiers in Biomedical Technologies
Serial Year :
2020
Record number :
2646377
Link To Document :
بازگشت