Title of article :
NOVEL APPROACH REGARDING ZETA POTENTIAL VARIATION AS A CONSEQUENCE OF A WOVEN FABRICS ANTIBACTERIAL FINISHING TREATMENT
Author/Authors :
BROASCA, Gianina “Gheorghe Asachi”Technical University of Iasi - Faculty of Textiles - Leather and Industrial Management, Romania , SUCHEA, Mirela Petruta Technological Educational Institute of Crete - School of Applied Technology - Electrical Engineering Department, Greece , CIOCOIU, Mihai “Gheorghe Asachi”Technical University of Iasi - Faculty of Textiles - Leather and Industrial Management, Romania , FARIMA, Daniela “Gheorghe Asachi”Technical University of Iasi - Faculty of Textiles - Leather and Industrial Management, Romania , VRINCEANU, Narcisa “Al.I.Cuza” University of Iasi - Faculty of Chemistry - Department of Materials Chemistry, Romania , VRINCEANU, Narcisa “Lucian Blaga” University of Sibiu - Faculty of Engineering - Department of Industrial Machinery and Equipment, Romania , CAMPAGNE, Christine Ecole Nationale Supérieure des Arts et Industrie Textiles (ENSAIT), France , RIMBU, Cristina “Ion Ionescu de la Brad” University of Agricultural Sciences and Veterinary Medicine of Iasi - Department Public Health, Romania , IORGOAEA, Mirela “Gheorghe Asachi”Technical University of Iasi - Faculty of Textiles - Leather and Industrial Management, Romania
From page :
43
To page :
48
Abstract :
Police uniforms made of polyester fibres should present a high level of antimicrobial protection, with respect to the environmental conditions they are worn in. Based on this the present research was conducted on polyester fibre woven fabrics, previously treated with zinc oxide with various concentrations for improved antimicrobial properties. The main parameter used to quantify the time stability of the antimicrobial treatment was Zeta Potential and its variation. The degradation of the antimicrobial treatment during the period of uniform wearing was simulated through repeated washes in the laboratory and its stability was estimated by estimation of the Zeta Potential. Zeta Potential values belonging to specimens treated with zinc oxide suspensions with different concentrations, before and after washing decreased with the increase of zinc oxide concentration, but its stability was noticeable.
Keywords :
Police uniform , Zinc oxide , Zeta Potential measurement , Air passing permeability , Water vapours passing endurance
Journal title :
Journal Of Textile an‎d Apparel
Journal title :
Journal Of Textile an‎d Apparel
Record number :
2646693
Link To Document :