Title of article :
UV-radiation Dose Assessment for Lexan Track Detector by Using of UV-visible and FTIR Spectroscopy Techniques
Author/Authors :
al-jobouri, hussain a. nahrain university - college of science - department of physics, Baghdad, Iraq , taha, fala hatem al-nahrain university - college of science - department of physics, Baghdad, Iraq
From page :
96
To page :
100
Abstract :
In the present work, studies the effect UV-radiation dose(1 J/cm²- 360 J/cm²) with power 15 W to Lexan track detector thickness175 μm. Absorbance –A was measured at wavelength 300 nm and 305 nm by using UV-visiblespectroscopy and measure the transmission percent–T% and deviation at the wave number-w 940cm-1 by using Fourier infrared –FTIR spectroscopy. The relationship between the radiation dose of the UV-radiation (J/cm²) and the absorbance-Aat wavelength 300 nm and 305 nm and the wave number-w 940 cm-1 was calculate as a polynomial relation .The present study show that there is a possibility to use the detector Lexan to assessment doses of exposure to UV-radiation in the medical and environmental fields .
Keywords :
Track Detector , Lexan , UV , UV–visible , FTIR.
Journal title :
Al-Nahrain Journal Of Science
Journal title :
Al-Nahrain Journal Of Science
Record number :
2646771
Link To Document :
بازگشت