Title of article :
DEVELOPMENT AND VALIDATION OF HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR ANALYSIS OF SIBUTRAMINE HYDROCHLORIDE AND ITS IMPURITY
Author/Authors :
CHANDORKAR, JG Aarti Drugs Ltd., India , KOTWAL, VB Aarti Drugs Ltd., India , DHANDE, NS Aarti Drugs Ltd., India , PACHPOR, MP Aarti Drugs Ltd., India , PANDE, VV Aarti Drugs Ltd., India
Abstract :
A simple, Precise, Rapid reproducible and selective reverse phase HPLC method has been developed for the estimation of Sibutramine Hydrochloride monohydrate and its Impurity in Bulk as well as Formulation. The analyte was resolved by using Mobile phase (Sodium Dihydrogen phosphate and Acetonitrile) at the flow rate of 1.0 Ml/Min. on Isocratic HPLC system consisting of Jasco Make UV visible Detector of model UV 1575 Jasco make HPLC pump of model PU 1580.An ODS C- 8 RP Column (4.6mm ID, 250mm L, particle size 5 Micron, at wavelength of 230 nm.
Keywords :
Sibutramine hydrochloride , impurity* , 5 , (2R) , 2 , aminopropyl) , 2 , methoxybenzene sulphonamide
Journal title :
Pakistan Journal Of Pharmaceutical Sciences
Journal title :
Pakistan Journal Of Pharmaceutical Sciences