Title of article :
Evaluation efficiency for mobile as discharge measurement device for partially filled circular channel
Author/Authors :
Rashwan, I.M.H. Tanta University - Faculty of Engineering - Irrigation and Hydraulic Engineering Department, Egypt , Idress, M.I. Tanta University - Faculty of Engineering - Irrigation and Hydraulics Engineering Department, Egypt
From page :
199
To page :
206
Abstract :
Discharge measurement is an important step in engineering applications such as sewerage system, irrigation and drainage system. Mobile flume is a simple and low-cost discharge measuring device constructed of two pieces of pipes, one installed vertically inside the other. The circular mobile flume depends on the concept of developing a contracted zone to have a control section. To evaluate the efficiency of this type of device mathematical and experimental studies are presented. Specific energy, discharge and Froude number equations are used to develop mathematical model. Experimental work is carried out to measure the discharge values corresponding to the specific energy values. The experimental data is used to evaluate the mobile flume as a device to measure discharge. A new equation for the discharge coefficient is presented. This equation can be used to determined accurate discharge with knowing the contraction ratio and measured specific energy.
Keywords :
Circular , Flow measurement , Mobile , Open channel , Partially filled
Journal title :
Ain Shams Engineering Journal
Journal title :
Ain Shams Engineering Journal
Record number :
2648823
Link To Document :
بازگشت