• Title of article

    PERFORMANCE DETERIORATION OF THERMOSIPHON SOLAR FLAT PLATE WATER HEATER DUE TO SCALING

  • Author/Authors

    ARUNCHALA, U.C. Manipal Institute of Technology - Department of Mechanical and Manufacturing Engineering, India

  • From page
    115
  • To page
    131
  • Abstract
    The performance of Flat plate Solar Water Heater deteriorates within five to twelve years of their installation due to factors related to manufacturing, operating conditions, lack of maintenance etc. Especially, problem due to scaling is significant as it is based on quality of water used. The remaining factors are system dependent and could be overcome by quality production. Software is developed by incorporating Hottel Whillier Bliss (H-W-B) equation to ascertain the effect of scaling on system efficiency in case of thermosiphon system. In case of clean thermosiphon system, the instantaneous efficiency calculated at 1000 W/m^2 radiation is 72 % and it drops to 46 % for 3.7 mm scale thickness. The mass flow rate is reduced by 90 % for 3.7 mm scale thickness. Whereas, the average temperature drop of water in the tank is not critical due to considerable heat content in water under severe scaled condition. But practically in case of major scale growth, some of the risers are likely to get blocked completely which leads to negligible temperature rise in the tank.
  • Keywords
    thermosiphon system , scaling , instantaneous efficiency , H , W , B equation
  • Journal title
    IIUM Engineering Journal
  • Journal title
    IIUM Engineering Journal
  • Record number

    2655932