Title of article :
Measurement of Indoor and Outdoor Background Ionising Radiation Levels of Kwali General Hospital, Abuja
Author/Authors :
JAMES, IU Nigeria Atomic Energy Commission - Nuclear Technology Centre, Nigeria , MOSES, IF Nigeria Atomic Energy Commission - Nuclear Technology Centre, Nigeria , VANDI, JN Nigeria Atomic Energy Commission - Nuclear Technology Centre, Nigeria , IKOH, UE Nigeria Atomic Energy Commission - Nuclear Technology Centre, Nigeria
From page :
89
To page :
93
Abstract :
Measurement of indoor and outdoor background ionising radiation level at Kwali General Hospital, Abuja, Nigeria was carried out using a well calibrated Geiger muller counter; Atomtex AT1117M radiation monitor. The dose equivalent results obtained range from 0.100±0.001 μSv/h to 0.124±0.007 μSv/h with an average of 0.107±0.003 μSv/h for indoor measurement while it ranges from 0.100±0.001 μSv/h to 0.122±0.003 μSv/h with an average of 0.108±0.003 μSv/h for outdoor measurement respectively. The obtained values are below the standard background radiation of 0.133 μSv/h. The study also revealed that the average annual equivalent dose rate is 0.750± 0.020 mSv/y and 0.189±0.005 mSv/y for indoor and outdoor measurements respectively. These results revealed that the dose levels in all of the locations (indoor and outdoor) were below the 1 mSv/y maximum permissible limit for the public set by International Commission on Radiological Protection (ICRP). Therefore, Kwali General Hospital is radiologically safe
Keywords :
Background ionising radiation , Geiger muller counter , radiation monitor , equivalent dose , indoor and outdoor measurement
Journal title :
Journal of Applied Sciences and Environmental Management
Journal title :
Journal of Applied Sciences and Environmental Management
Record number :
2659252
Link To Document :
بازگشت