Title of article :
Conographic Diagnosis of Infantile Hypertrophic Pyloric stenosis- Use of Simultaneous Grey-scale Colour Doppler Examination Mehboob Hussain
Author/Authors :
Hussain, Mehboob Qassim University - College of Medicine - Department of Radiology Imaging, Saudi Arabia
Abstract :
Objective: To evaluate the accuracy of Ultrasound in the diagnosis of Infantile Hypertrophic Pyloric stenosis, especially with simultaneous use of grey-scale colour doppler examination of pylorus. Methods: Fifty two infants with suspected Infantile Hypertrophic Pyloric stenosis (IHPS) were evaluated with grey-scale and colour Doppler examination. The sonographic findings were categorized as positive IHPS, negative IHPS and equivocal cases. Positive songraphic findings in 21 infants (40%) were confirmed at surgery. Negative sonographic findings in 27 infants (52%) were followed by ward chart reviews. Results: Sensitivity, Specificity and Accuracy of grey-scale colour doppler examination for the diagnosis of IHPS were 100%. Conclusion: Sonography is the method of choice for the diagnosis of IHPS. Simultaneous greyscale and colour Doppler examination of pylorus for suspected IHPS is more accurate than simple grey-scale sonography.
Keywords :
Grey , scale Sonography , Colour Doppler examination , Infantile Hypertrophic Pyloric stenosis , experienced radiologists.