Title of article :
Comparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom
Author/Authors :
Baghani, H.R. shahid beheshti university - Nuclear Engineering Faculty - Radiation Medicine Department, تهران, ايران , Aghamiri, S.M.R. shahid beheshti university - Nuclear Engineering Faculty - Radiation Medicine Department, تهران, ايران , Gharaati, H. Cancer Institute of Tehran - Radiotherapy Physics Department, ايران , Mahdavi, S.R. iran university of medical sciences - Medical Faculty - Medical Physics Department, ايران , Hosseini Daghigh, S.M. shahid beheshti university - Nuclear Engineering Faculty - Radiation Medicine Department, تهران, ايران
From page :
151
To page :
158
Abstract :
Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the software used for treatment planning is to investigate the radiotherapy and treatment planning by means of a anthropomorphic Rando phantom which was used here for treatment planning and practical dosimetry for craniospinal radiotherapy. Studying the absorbed dose by the organs at risk was the secondary objective discussed in this paper. Materials and Methods: Treatment planning in craniospinal radiotherapy was done using CorePlan 3D treatment planning software. Radiotherapy was administered on a anthropomorphic Rando phantom and practical dosimetry was done using GR-200 TLDs. Varian Clinac 2100C/D was used for radiotherapy. Results: The absorbed dose by regions of interest was separately calculated for treatment planning and radiotherapy. Except the conjunction areas of the cranial and spinal radiation fields, the difference among the results was not more than 5%. Full comparison of the results for each part has been presented. Conclusion: The comparison the results of practical dosimetry and treatment planning software supports the validity of CorePlan treatment planning system. Also analysis of the absorbed dose through organs at risk showed that the absorbed dose by organs at risk have an acceptable value with respect to tolerance dose of these organs. The only unacceptable result was related to thyroid.
Keywords :
Craniospinal radiotherapy , rando phantom , thermoluminescence dosimetry , treatment planning.
Journal title :
International Journal of Radiation Research
Journal title :
International Journal of Radiation Research
Record number :
2666505
Link To Document :
بازگشت