• Title of article

    Study the Effect of Temperature on the Performance of Hollow Fiber Membrane Bioreactor in Wastewater Treatment

  • Author/Authors

    Ali, Safaa A. Baghdad University - Genetic Engineering and Biotechnology Institute for Postgraduate Studies, Iraq , Fathel, Qusay AL-Technology University - College of Engineering, Iraq , Mohammed, Alaa K. Baghdad University - Genetic Engineering and Biotechnology Institute for Postgraduate Studies, Iraq

  • Pages
    5
  • From page
    25
  • To page
    29
  • Abstract
    A membrane bioreactor (MBR) is one of the modifications to the conventional activated sludge process, since it is the combination of a membrane module and a bioreactor. In the present study, 100 liters lab-scale aerobic MBR was seeded with 1.5 Liter activated sludge and municipal wastewater from AL-Rustumiya municipal wastewater treatment station, two hollow fibers sample (MI,MII) manufactured in the University of Technology/ Chemical Engineering Department, were used as biomembranes. Trans membrane pressure TMP was studied and it was found that the optimum value of TMP was 10 cm Hg vacuum which gave optimum effluent flux 400 ml/hr for MI and 350 ml/hr for MII. The experimental work involves the effect of temperature 25, 35, 45°C on the performance of the MBR fibers sample (MI, MII) and its effect on biomass growth and removal efficiency of the COD, BOD. Both samples show good performance in 25°C.
  • Keywords
    Hollow Fiber Membrane , Bioreactor , Wastewater
  • Journal title
    Journal Of Biotechnology Research Center
  • Serial Year
    2014
  • Journal title
    Journal Of Biotechnology Research Center
  • Record number