Title of article
A comparison of intra cuff pressures in high-flow and low-flow nitrous oxide anesthesia
Author/Authors
Postaci, Aysun Numune Education and Research Hospital - Department of 2nd Anesthesiology and Reanimation, Turkey , Karabeyoglu, Isil Numune Education and Research Hospital - Department of 2nd Anesthesiology and Reanimation, Turkey , Erk, Gulcan Numune Education and Research Hospital - Department of 2nd Anesthesiology and Reanimation, Turkey , Ayerden, Taner Numune Education and Research Hospital - Department of 2nd Anesthesiology and Reanimation, Turkey , Sastim, Handan Numune Education and Research Hospital - Department of 2nd Anesthesiology and Reanimation, Turkey , Barcin, Semiha Numune Education and Research Hospital - Department of 2nd Anesthesiology and Reanimation, Turkey , Dikmen, Bayazit Numune Education and Research Hospital - Department of 2nd Anesthesiology and Reanimation, Turkey
From page
1719
To page
1722
Abstract
Objectives: To investigate intra cuff pressure changes in low-flow anesthesia (LFA) and high-flow (HFA) N2O anesthesia during moderate-duration surgical procedures.Methods: We carried out this prospective, randomized, single blind study at Numune Educational and Research Hospital, Ankara, Turkey between January to December 2005. Seventy patients aged between 18-65 years, American Society of Anesthesiologists (ASA) physical status grades I-III, undergoing elective surgery were enrolled in this study. Following a standardized induction, anesthesia was maintained with isoflurane (end-tidal 0.9-1%) at 4 L/minute for the HFA group, or 1 L/minute for the LFA group fresh gas flows. Endotracheal tube cuff (intra cuff) pressures were measured continuously with a pressure manometer, and inspired oxygen and N2O levels were noted every 10 minutes throughout the study.Results: There was no significant difference between HFA and LFA groups for initial (first) cuff pressures (mean+/-SD, HFA=20.9+/-4.19, LFA=20.4+/-4.11, cmH2O), and maximum cuff pressures (MCP) (mean+/-SD, HFA=32.3+/-18.74, LFA=33.5+/-8.89, cmH2O) (p 0.05). The time to reach the maximum intra cuff pressure was significantly shorter in the LFA group (77.4+/-20.33 minutes), than the HFA group (89.3+/-23.94 minutes), (p=0.038). Between the tenth and nineteenth minutes, inspired oxygen level was significantly higher in the HFA group (p=0.001), whereas inspired N2O was significantly higher in the LFA group (p=0.001).Conclusion: The intra cuff pressures should be monitored carefully during LFA, since the duration to reach the maximum intra cuff pressures was shorter than that of HFA
Journal title
Saudi Medical Journal
Journal title
Saudi Medical Journal
Record number
2680429
Link To Document