• Title of article

    Comparison of endothelial function of coronary artery bypass grafts in diabetic and nondiabetic patients: Which graft offers the best?

  • Author/Authors

    Gür, Demet Özkaramanlı Tekirdağ State Hospital - Department of Cardiology, Turkey , Gür, Özcan Nami‎k Kemal University - Faculty of Medicine - Department of Cardiovascular Surgery, Turkey , Gürkan, Selami Namık Kemal University - Faculty of Medicine - Department of Cardiovascular Surgery, Turkey , Cömez, Selcem Namık Kemal University - Faculty of Medicine - Department of Pharmacology, Turkey , Gönültaş, Aylin Tekirdağ State Hospital - Department of Pathology, Turkey , Yılmaz, Murat Namık Kemal University - Faculty of Medicine - Department of Endocrinology, Turkey

  • From page
    657
  • To page
    662
  • Abstract
    Objective: Diabetes associated endothelial dysfunction, which determines both long and short term graft patency, is not uniform in all coronary artery bypass surgery (CABG) grafts. Herein this study, we aimed to investigate the degree of endothelial dysfunction in diabetic radial artery (RA), internal mammarian artery (IMA) and saphenous vein (SV) grafts in vitro tissue bath system.Methods: This is a prospective experimental study. Fifteen diabetic and 15 non-diabetic patients were included to the study. A total number of 96 graft samples were collected; 16 graft samples for each graft type from both diabetic and non-diabetic patients. Arterial grafts were harvested with pedicles and SV grafts were harvested by ‘no touch’ technique. Vasodilatation response of vascular rings to carbachol, which induces nitric oxide (NO) mediated vasodilatation, was designated as the measure of endothelial function.Results: The IMA grafts had the most prominent NO mediated vasodilatation in both diabetic and non-diabetic patients, concluding a better preserved endothelial function than SV and RA. The ‘no- touch’ SV and RA grafts had similar vasodilatation responses in non-diabetic patients.In diabetic patients, on the other hand, RA grafts exhibited the least vasodilatation response (ie. worst endothelial function), even less vasodilatation than ‘no touch’ SV grafts (p 0.0001).Conclusion: Deteriorated function of RA grafts in diabetic patients, even worse than SV grafts made evident by this study, encourages the use of ‘no touch’ technique as the method of SV harvesting and more meticulous imaging of RA before its use as a graft in diabetic patients.
  • Keywords
    endothelial function , coronary artery bypass grafts , tissue bath study
  • Journal title
    The Anatolian Journal of Cardiology: Andolu Kardiyoloji Dergisi
  • Journal title
    The Anatolian Journal of Cardiology: Andolu Kardiyoloji Dergisi
  • Record number

    2693021